Square Shaft Helical Piers Ground Screw Foundation Helical Piles for Modular Prefab House

Product Details
Customization: Available
Finish: Hot-Dip Galvanized
Installation Method: Manual Installation
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Square Shaft Helical Piers Ground Screw Foundation Helical Piles for Modular Prefab House
  • Square Shaft Helical Piers Ground Screw Foundation Helical Piles for Modular Prefab House
  • Square Shaft Helical Piers Ground Screw Foundation Helical Piles for Modular Prefab House
  • Square Shaft Helical Piers Ground Screw Foundation Helical Piles for Modular Prefab House
  • Square Shaft Helical Piers Ground Screw Foundation Helical Piles for Modular Prefab House
  • Square Shaft Helical Piers Ground Screw Foundation Helical Piles for Modular Prefab House
Find Similar Products

Basic Info.

Model NO.
MONO 468
Material
Steel
Type
Sand Anchor
Steel Grade
80 Grade
MOQ
500 PCS
Application
as Deep Foundation
Quality Control
100% Inspection
Service
ODM OEM
Delivery Time
30~40 Days
Transportation
Container by Sea
Transport Package
Pallet
Specification
customised
Origin
China
HS Code
73082000
Production Capacity
100, 000 Ton Per Year

Packaging & Delivery

Package Size
580.00cm * 230.00cm * 230.00cm
Package Gross Weight
2000.000kg

Product Description


A complete Power Shaft Assembly consists of a lead helix section, extension(s) and guy termination other attachment.  The helix size (diameter) and number of helices are selected for the required holding strength.  The shaft size and rating is selected based on the necessary holding strength and installation torque requirement.  The guy attachment is chosen based on the number of guys

Extensions with helix are placed directly after the lead section (no bare extensions in between). They are used when additional bearing area is needed and to develop increased installation torque.

Hot Dip Galvanized per ASTM A123.

Square Shaft Helical Piers Ground Screw Foundation Helical Piles for Modular Prefab House

Consists of solid square shafts, ranging from 1.5″ to 2″. The piles are typically used for ultimate loads between 100 and 650 kN (25-150 kips) but have been tested to loads in excess of 900 kN (200 kips) in unique situations.
Square shaft products are generally used in small to moderate loading applications, and they provide excellent tension resistance. Square shaft piles are able to penetrate dense and cobble-rich soil when compared to their helical pipe pile equivalents, but they have lower resistance to buckling and negligible lateral load resistance.
In applications where tension is the primary consideration, we recommend the Square Shaft Piers. They have several advantages over the typical square shaft anchors.

Square Shaft Helical Piers Ground Screw Foundation Helical Piles for Modular Prefab House
Square Shaft Advantages:
•    Greater yield and Tensile strength
•    Patented Cross-bolt Connection
•    Increased safety factor
•    Higher torque capacity
•    Easy to install
•    Installs in any season
•    Minimal soil disturbance
•    Not affected by a high water table
Square Shaft Helical Piers Ground Screw Foundation Helical Piles for Modular Prefab House Applied Load
The loads that the structure will apply to the pile it connects to. These loads include the dead load, live load, lateral loads, and seismic loading that the pile is being used to resist.
Soil Parameters
Soil strength is reviewed to make sure that it can withstand the load applied by the pile and helix plates.
Pile Capacity
The amount of load that a pile can resist. The pile shaft and connection are selected to resist the applied load. The helix plates are designed based on soil information to ensure that they are the right size.

Termination brackets transfer the load to the pile at the head. The termination bracket is connected to the foundation, typically by attaching it to or casting it into a concrete foundation, or directly to a steel grillage structure.

Composition:
•    square solid shaft 1 1/2" thru 2″ O.D. typical.
•    Solid round cornered Square (RCS), yield strength of grade 70 or 90. 
•    Ultimate compression/tension axial capacity: 57 to 200 kip. 
•    Circular tapered plates (helices) are welded to the center of the shaft.
•    Helix diameters can range between 6″ - 48″
•    with a thickness of 3/8″ - 1″.
•    Helix pitch will range from 3″ - 6″
•    Hot dipped galvanized per ASTM A123 or bare steel options available
•    Coupling bolts are heavy hex bolt as per ASTM A325
•    All welding to be done by welders certified of the AWS CODE D1.1