Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors

Product Details
Customization: Available
Finish: Hot-Dip Galvanized
Installation Method: Powered Installation
Manufacturer/Factory, Trading Company
Gold Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors
  • Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors
  • Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors
  • Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors
  • Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors
  • Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors
Find Similar Products

Basic Info.

Model NO.
MONO 468
Material
Steel
Type
Helical Anchor
Steel Grade
80 Grade
MOQ
500 PCS
Quality Control
100% Inspection
Service
ODM OEM
Delivery Time
30~40 Days
Transportation
Container by Sea
Transport Package
Pallet
Specification
customised
Origin
China
HS Code
73082000
Production Capacity
100, 000 Ton Per Year

Product Description

A helical pier is a deep foundation. Its purpose is to transfer a structural load to deeper, stronger, and less compressible materials bypassing any weaker and more compressible materials that would be unsuitable for the support of a conventional shallow foundation.  As a deep foundation, a helical pier should be considered for most applications that would call for a driven pile, drilled pier, or mini pile. Helical piles and anchors are usually a great foundation solution to any of the applications below whether it's a new build or existing structure.

 

  • Commercial Buildings
  • Mobile Home Anchors
  • Tilt-up Wall Anchors
  • Work Camp Foundations Towers - Quad Base
  • Transmission Towers - Monotube
  • Utility Anchoring
  • Substations
  • Lighting <50FT
  • Sound Walls
  • Bridges/Boardwalks/Docks
  • Roadway Signage Traffic Signals Billboards/Signage Generator Bases
  • Tie-Downs/Moorings
  • Tie-Backs/Wall Anchors Retaining Walls
  • Bulkheads
  • Shoring Pipeline
  • Guy Lines/Wires
  • Tanks and Silos
  • Underwater Support
  • Machine Bases



item no.  76/f219/88.9*1600/18002100/2500mm*200F10.1

material :steel ,iso 630fe360a

surface:galvanized to din en iso 1461

length:2000mm/1800mm/1600mm/

quter:76mm/88.9/219mm

thickness:3-4mm
 

A complete Power Shaft Assembly consists of a lead helix section, extension(s) and guy termination other attachment.  The helix size (diameter) and number of helices are selected for the required holding strength.  The shaft size and rating is selected based on the necessary holding strength and installation torque requirement.  The guy attachment is chosen based on the number of guys

Extensions with helix are placed directly after the lead section (no bare extensions in between). They are used when additional bearing area is needed and to develop increased installation torque.
Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors
Specifications:

DIAMETER SHAFT-  3/4″, 1/2",3/4",5/8" etc.
LENGTH-  36 INCHES etc.
Eye- 1.5″ Diameter LOOP IS WELDED CLOSED
HELICAL DISC SIZES- 4 INCH AND 6 INCH
FINISH - HDG (HOT DIP GALVANIZED)
PULL OUT RESISTANCE- UP TO 4000 LBS (HARD PAN SOIL)
Screw in Ground Anchor 3/4" x 36" w/ 4" & 6" Helices Galvanized
4″ LEAD HELIX HELPS EASE THE INSTALLATION OF THE LARGER 6″ HELIX
HOT DIP GALVANIZED TO: ASTM SPECIFICATION A123 IDEAL FOR CORROSIVE ENVIRONMENT OR LONG DURATION INSTALLATIONS
RE-USEABLE - CAN BE UNSCREWED AND REINSTALLED

Every new construction project needs a strong foundation. new construction must take place on soils with poor load-bearing characteristics. Even if you are building on ground that is stable, it is a good idea to reinforce the foundation to prevent settlement.

Without a solution to overcome the limitations of poor soil, even well-constructed homes are likely to suffer with settlement issues. Footings and foundation walls will crack and bulge. Chimneys will tilt and separate. Homes, buildings and concrete slabs will crack and buckle.

Fortunately, structural engineers have developed techniques to give buildings and other structures a solid, stable structure in spite of poor soil conditions. When you need added support for your structure's foundation, using helical piers from Tianyicool is one of the strongest and most easily installed options available.
Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors
Hot Dip Galvanized per ASTM A123.
Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors

Consists of solid square shafts, ranging from 1.5″ to 2″. The piles are typically used for ultimate loads between 100 and 650 kN (25-150 kips) but have been tested to loads in excess of 900 kN (200 kips) in unique situations.
Square shaft products are generally used in small to moderate loading applications, and they provide excellent tension resistance. Square shaft piles are able to penetrate dense and cobble-rich soil when compared to their helical pipe pile equivalents, but they have lower resistance to buckling and negligible lateral load resistance.
In applications where tension is the primary consideration, we recommend the Square Shaft Piers. They have several advantages over the typical square shaft anchors.

Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors
Square Shaft Advantages:
•    Greater yield and Tensile strength
•    Patented Cross-bolt Connection
•    Increased safety factor
•    Higher torque capacity
•    Easy to install
•    Installs in any season
•    Minimal soil disturbance
•    Not affected by a high water table
Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors 
Composition:
•    square solid shaft 1 1/2" thru 2″ O.D. typical.
•    Solid round cornered Square (RCS), yield strength of grade 70 or 90. 
•    Ultimate compression/tension axial capacity: 57 to 200 kip. 
•    Circular tapered plates (helices) are welded to the center of the shaft.
•    Helix diameters can range between 6″ - 48″
•    with a thickness of 3/8″ - 1″.
•    Helix pitch will range from 3″ - 6″
•    Hot dipped galvanized per ASTM A123 or bare steel options available
•    Coupling bolts are heavy hex bolt as per ASTM A325
•    All welding to be done by welders certified of the AWS CODE D1.1

Steel Structure Piling Hot Dipped Galvanized Helical Piles Pier Ground Screw Earth Anchors

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier